Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • INDOOR AIR QUALITY AQ5000Pro (Quest Technologies)
Produk atau jasa ini sudah tidak dijual, silakan hubungi perusahaan bersangkutan untuk keterangan lebih lanjut.

INDOOR AIR QUALITY AQ5000Pro (Quest Technologies)

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail INDOOR AIR QUALITY AQ5000Pro (Quest Technologies)

AQ5000Pro IAQ Monitor Technical Specifications Measured Parameters: Carbon Dioxide: * Detector NDIR (non-dispersive infrared) * Range User Selectable * 0 to 5,000 and 0 to 20,000 ppm * Accuracy 0 to 5,000 ppm: +/-3% of reading +/-50 ppm * 0 to 20,000 ppm: +/-3% of reading +/-300 ppm Temperature Influence Additional +/-0.2% of reading +/-2 ppm for each °C * Resolution 1 ppm (10 ppm above 10,000 ppm) * Response Time 22 seconds for 63% of final value; 70 seconds for 10-90% of 4000 ppm change Relative Humidity: * Detector Capacitive * Range 0-100% non-condensing * Accuracy +/-3% @ 25°C * Resolution 0.1% * Response Time 50 seconds with min air flow of 1 mi/hr * (.45 meters/sec) through wand Temperature: * Detector Thermistor * Range 0 to 60°C (+32 to +140°F) * Accuracy +/-5°C (+/-0.9 °F) requires min air flow of 1 mi/hr (.45 meters/sec) through wand * Resolution 0.1 oC Dew Point: * Range -65 °C/+60 °C * Resolution 0.1 °C Gas: * Detector O2, CO, H2S, SO2, CL2, NO2, NO, HCN & NH3 * Resolution 0.1, 0.5 or 1 ppm depending on sensor in use Air Velocity: * Detector Hot-Wire * Range 0-20 m/s * Accuracy +/- 5% * Resolution 0.1 m/s Linear: * Range +/-1 V * Accuracy +/-2% of full scale * Resolution 0.001 Vdc Data Storage: * 57,344 total samples Display: * 20 character x 4 lines backlit LCD Real Time Clock: * 0.01% accuracy Storage Rate: * 1 sec, 1 min, 5 min, 10 min or 15 min sample or averages Statistics Saved: * Up to 5 data values per sampling interval (CO2, temperature, humidity, dew point, gas and linear and air velocity input) Communications: * Format RS-232, 1 start, 8 data, 1 stop bit, no parity * Baud Rate 1200 to 38400 Printer Output: Summary Report includes: * Separate reports for each logging session indicating minimum, maximum & time of occurrence, elapsed time & average per session. * Gas readings include: TWA & STEL Time History Report Includes: All recorded data values with date & time stamp Power: * Internal Power: "AA" Alkaline Batteries - >15 hrs @ 25°C (77°F) * Rechargeable NiMH Battery Pack: 7 hrs @ 25°C (77°F) (Data Retention 30 days in the event of low battery) * External Power: +6.0 Vdc output AC power adapter, 120 VAC or 240v Environments: * Operating Temperature: 0 to +50°C (+32 to +122°F) * Storage Temperature: -20 to +60°C (-4 to +140°F) Size: * Enclosure Size 3.6 x 7.1 x 1.3" (9.1 x 18.0 x 3.3 cm) * Wand Size 11.8" (30cm) long, 1" (2.54 cm) diameter Weight: * 2 lbs. (0.83 kg)
Tampilkan Lebih Banyak